BioNTech Results Presentation Deck
Omicron-BA.1 Adapted Vaccines as 4th Dose Elicit Improved
Omicron Neutralization Response
FFRNT 50
10,000
1,000
100
10
Participants WITHOUT evidence of infection up to 1 month after first study vaccination
>55 yrs old participants, 30 and 60 µg dose
501.1
78.4
OMI 30 µg
n=17
822.0
145.3
OMI 60 µg
n=18
BA.1
BA.4/5
Internal data.
FFRNT, fluorescent foci reduction neutralization test; LOD, limit of detection. GMR, geometric mean ratio
1 GMR superiority criterion: the lower bound of 95% confidence interval for GMR is >1.0
13
2 Non-inferiority criterion: the lower bound of 95% confidence interval for interval for the percentage difference is >-5
3 GMR "super" superiority criterion: the lower bound of 95% confidence interval for GMR is >1.5
771.3
226.3
Bivalent 30 µg
n=13
678.1
137.2
Bivalent 60 µg
n=18
LOD
Superiority¹ for GMR and non-inferiority2 for sero responses (monovalent and bivalent vaccines)
"Super" superiority³ for GMR (monovalent vaccines); Neutralization activity against BA.4/5 reduced